Extension Cord Helper
By Sam Shah · Updated
Extension cord gauge depends on current, cord length, and voltage; follow the appliance and cord ratings.
Quick Facts
- •Lower AWG = thicker wire = more capacity
- •12 AWG handles up to 20A at 50ft
- •Never exceed 80% of cord rating
- •Don't use indoor cords outdoors
Extension Cord Safety
Using an undersized extension cord can cause overheating and fire. The required wire gauge depends on the load (amps) and cord length. Longer runs need thicker wire (lower AWG number). Never daisy-chain extension cords or exceed the rated capacity. You can also check electrical quantities with our volts/amps/watts calculator and our kw to horsepower converter, convert energy or power units with our kwh to joules converter, or read the background in Save Money on Energy Bills: Temperature Settings Guide.
How does Extension Cord Helper work?
An extension cord that is too thin for the load drops voltage along its length, which makes motors run hot and can melt insulation. Gauge is counted backwards: a 12 gauge cord is thicker than a 16 gauge one. Length matters just as much as gauge, because voltage drop rises with distance.
Worked examples
Gauge for a 13 amp saw on a 100 ft cord
- 1Load is 13 amps, which sits in the 11 to 13 amp band.
- 2At 25 ft, 16 gauge would do. At 100 ft, that band requires 12 gauge.
- 3Confirm the cord is rated for outdoor use if the saw is outside.
A 12 gauge, 100 ft outdoor rated cord.
Voltage drop on a 50 ft, 14 gauge cord at 12 amps
- 114 gauge copper has about 2.53 ohms per 1,000 ft.
- 2The current travels out and back, so use twice the length: 100 ft.
- 3Resistance: 100 ÷ 1,000 × 2.53 = 0.253 ohms.
- 4Drop = amps × ohms = 12 × 0.253 = 3.04 volts, or 2.5 percent of 120 V.
About 3 volts of drop, within the 3 percent guideline but close to the limit.
Minimum wire gauge by load and cord length at 120 V
| Amps | 25 ft | 50 ft | 100 ft | 150 ft |
|---|---|---|---|---|
| 0 to 5 | 16 | 16 | 16 | 14 |
| 6 to 8 | 16 | 16 | 14 | 12 |
| 9 to 10 | 16 | 16 | 14 | 12 |
| 11 to 13 | 16 | 14 | 12 | 10 |
| 14 to 15 | 14 | 12 | 12 | 10 |
| 16 to 20 | 12 | 12 | 10 | 10 |
Lower gauge numbers mean thicker wire. When in doubt, go thicker.
Cord jacket ratings
| Code | Meaning |
|---|---|
| S | Flexible service cord |
| J | 300 volt insulation, standard household |
| T | Vinyl thermoplastic jacket |
| O | Oil resistant |
| W | Rated for outdoor and wet locations |
| E | Elastomer, stays flexible in cold |
SJTW is the common outdoor household cord. SJOOW handles oil and cold on a job site.
Practical tips
- •Uncoil the cord fully before use. A coiled cord under load traps heat and can reach damaging temperatures.
- •Do not daisy chain cords. Use one longer cord instead, since each connection adds resistance and a failure point.
- •Check the cord for warmth after ten minutes of use. Anything warmer than mildly is a sign the gauge is too small.
Frequently asked questions
How much voltage drop is acceptable?
Three percent is the usual working limit for a branch circuit, so about 3.6 volts on a 120 volt supply. Motors and heaters are the most sensitive to anything beyond that.
Can I use an indoor cord outside for a short job?
It is not safe. Indoor jackets crack in cold and absorb moisture, which creates a shock hazard. Outdoor cords carry a W in the code, such as SJTW.
Does a power strip change the requirement?
Yes. Add the load of everything plugged in and size the cord for that total, not for the largest single item. Power strips also should never be plugged into another power strip.